ATMARS AH Series is able to simulate a wide range of temperature and humidity environments, that temperatures ranging from -70°C to +150°C and humidity range from 20%R.H to 98%R.H. ATMARS can also offer you the best solutions based on your own requirements.
ATMARS AH Series is able to simulate a wide range of temperature and humidity environments, that temperatures ranging from -70°C to +150°C and humidity range from 20%R.H to 98%R.H. ATMARS can also offer you the best solutions based on your own requirements.
High-low temperature & humidity test chamber description:
High-low temperature & humidity test chamber is widely used in testing various types of materials for their tolerances of heat, cold, dry and humidity. It is designed for quality inspection for all types of electronic products, electric appliance, and products from communication, military, automobile, plastic, metal, chemical, building materials, medical and aerospace industries. Unique design with high-quality material, whether you’re testing which kind of samples, our High low alternating temperature and humidity test chamber can give you a perfect solution.
Product Features:
The compact design of the chamber structure and less space demand. Fully considered the safe, reliable, energy-efficient, and environmentally friendly technology on refrigerating system design. Temperature and humidity control set up by touch-screen inputs.
High-low temperature & humidity test chamber description:
High-low temperature & humidity test chamber is widely used in testing various types of materials for their tolerances of heat, cold, dry and humidity. It is designed for quality inspection for all types of electronic products, electric appliance, and products from communication, military, automobile, plastic, metal, chemical, building materials, medical and aerospace industries. Unique design with high-quality material, whether you’re testing which kind of samples, our High low alternating temperature and humidity test chamber can give you a perfect solution.
Product Features:
The compact design of the chamber structure and less space demand. Fully considered the safe, reliable, energy-efficient, and environmentally friendly technology on refrigerating system design. Temperature and humidity control set up by touch-screen inputs.
Cooling mode |
水冷式 |
Impact range of high temperature tank |
+60℃ ~ +200℃ |
Impact range of cryogenic tank |
-70℃ ~ 0℃ |
High temperature tank temperature setting range |
+60℃ ~ +200℃ |
Cryogenic tank temperature setting range |
-75℃ ~ 0℃ |
Heating time of high temperature tank |
Normal temperature→+200℃≤15min |
Cooling time of cryogenic tank |
Normal temperature→-75℃≤55 min |
Impact recovery time |
-65℃ ~ +150℃ About 5min, no load (the sensor is placed at the unit outlet) |
Recovery condition |
High temperature exposure: +150℃ 15min
Low temperature exposure: -65℃ 15min
Sample weight: 3.5kg (plastic encapsulated IC, distributed in 2 sample baskets) (sensor location: upper tuyre side of the sample) |
Temperature uniformity |
±2.0℃ |
Temperature fluctuation |
±0.5℃ |
Temperature deviation |
±2.0℃(≤+150℃时) ±3.0℃(>+150℃时) |
High and low temperature impact constant temperature time |
15min以上 |
The temperature performance test is measured according to the relevant provisions of IEC60068-3-5:2001 standard; The sensor is placed at the unit air outlet; All the acceptance indicators are measured when the ambient temperature or the inlet water temperature of cooling water is +10 ~ +25℃, if it exceeds this range, it will affect the temperature change rate The temperature rate makes a difference. |
Cooling mode |
水冷式 |
Impact range of high temperature tank |
+60℃ ~ +200℃ |
Impact range of cryogenic tank |
-70℃ ~ 0℃ |
High temperature tank temperature setting range |
+60℃ ~ +200℃ |
Cryogenic tank temperature setting range |
-75℃ ~ 0℃ |
Heating time of high temperature tank |
Normal temperature→+200℃≤15min |
Cooling time of cryogenic tank |
Normal temperature→-75℃≤55 min |
Impact recovery time |
-65℃ ~ +150℃ About 5min, no load (the sensor is placed at the unit outlet) |
Recovery condition |
High temperature exposure: +150℃ 15min
Low temperature exposure: -65℃ 15min
Sample weight: 3.5kg (plastic encapsulated IC, distributed in 2 sample baskets) (sensor location: upper tuyre side of the sample) |
Temperature uniformity |
±2.0℃ |
Temperature fluctuation |
±0.5℃ |
Temperature deviation |
±2.0℃(≤+150℃时) ±3.0℃(>+150℃时) |
High and low temperature impact constant temperature time |
15min以上 |
The temperature performance test is measured according to the relevant provisions of IEC60068-3-5:2001 standard; The sensor is placed at the unit air outlet; All the acceptance indicators are measured when the ambient temperature or the inlet water temperature of cooling water is +10 ~ +25℃, if it exceeds this range, it will affect the temperature change rate The temperature rate makes a difference. |