Altitude test chambers combined temperature and altitude/vacuum with optional humidity to test basic components or sub-assemblies designed for use in a variety of industries, such as aviation, aerospace, communication, military, automotive, electronics and other industries.. With ATMARS altitude chambers, users can control the temperature environment for testing while simulating various altitudes from site level to over 10,000 feet (Customizable).
Altitude test chambers combined temperature and altitude/vacuum with optional humidity to test basic components or sub-assemblies designed for use in a variety of industries, such as aviation, aerospace, communication, military, automotive, electronics and other industries.. With ATMARS altitude chambers, users can control the temperature environment for testing while simulating various altitudes from site level to over 10,000 feet (Customizable).
Altitude test chamber description:
Altitude test chambers combine temperature and altitude/vacuum with optional humidity to test basic components or sub-assemblies designed for use in various industries, such as aviation, aerospace, communication, military, automotive, electronics and other industries.. With ATMARS altitude chambers, users can control the temperature environment for testing while simulating various altitudes from site level to over 10,000 feet (Customizable).
ATMARS altitude chambers offer performance flexibility and reliability for today’s mixed-environment testing requirements with an overall temperature range of -70°C to +150°C(Customizable), optional humidity capabilities of 20% to 98% RH and altitude up to 100,000 feet. Optional extended ranges are also available to simulate sea level testing when your site is significantly above sea level.
Product Features:
High precision and stable performance with touch screen controller, friendly Man-Machine interface. Adopts international brands of imported parts for the cooling system to improve operation reliability. Water-cooled cooling system with semi-hermetic compressor. Balanced temperature and humidity control system (BTHC). Robust vacuum system for reliable and flexible tests viewing window with interior light and cable access ports available.
Altitude test chamber description:
Altitude test chambers combine temperature and altitude/vacuum with optional humidity to test basic components or sub-assemblies designed for use in various industries, such as aviation, aerospace, communication, military, automotive, electronics and other industries.. With ATMARS altitude chambers, users can control the temperature environment for testing while simulating various altitudes from site level to over 10,000 feet (Customizable).
ATMARS altitude chambers offer performance flexibility and reliability for today’s mixed-environment testing requirements with an overall temperature range of -70°C to +150°C(Customizable), optional humidity capabilities of 20% to 98% RH and altitude up to 100,000 feet. Optional extended ranges are also available to simulate sea level testing when your site is significantly above sea level.
Product Features:
High precision and stable performance with touch screen controller, friendly Man-Machine interface. Adopts international brands of imported parts for the cooling system to improve operation reliability. Water-cooled cooling system with semi-hermetic compressor. Balanced temperature and humidity control system (BTHC). Robust vacuum system for reliable and flexible tests viewing window with interior light and cable access ports available.
*Specifications of AHP Series Altitude test chamber (ATP series without humidity control.) |
||||||||
Model |
AHP-125 |
AHP-225 |
AHP-408 |
AHP-512 |
AHP-800 |
AHP-1000 |
AHP-2000 |
|
Temperature humidity adjustment mode |
Smart balanced temperature(humidity) control – BT(H)C |
|||||||
Performance |
Temperature range |
-20°C/-40°C/-70°C~+150°C |
||||||
Temperature fluctuation |
±0.5℃(At normal pressure) |
|||||||
Temperature uniformity |
±2.0°C (At normal pressure) |
|||||||
Temperature deviation |
±2.0℃(At normal pressure) |
|||||||
Cooling rate |
0.7°C~1.0°C/min (Overall average, at normal pressure) |
|||||||
Humidity range |
20%R.H~98%R.H (Work under normal pressure) |
|||||||
Humidity fluctuation |
±2.0%RH |
|||||||
Humidity uniformity |
±3.0%RH |
|||||||
Humidity deviation |
±3.0%RH (>75%RH), ±5.0%RH (≦75%RH) |
|||||||
Pressure range |
Normal pressure to 0.5kPa |
|||||||
Pressure deviation |
≦±2 kPa (≧40kPa),≦±5% (2 ~ 40kPa),≦±0.1 kPa(≦2kPa ) |
|||||||
Depressurization rate |
From normal pressure to 1kPa ≤30min |
|||||||
Pressure recovery rate |
10kPa/min(Adjustable) |
|||||||
Workspace volume |
125L |
225L |
408L |
512L |
800L |
1000L |
2000L |
|
Workspace dimensions (WxDxH)mm |
Width(mm) |
500 |
500 |
800 |
800 |
1000 |
1000 |
1000 |
Height(mm) |
500 |
750 |
850 |
800 |
1000 |
1000 |
1000 |
|
Depth(mm) |
500 |
600 |
600 |
800 |
800 |
1000 |
2000 |
|
Exterior dimensions (WxDxH)mm |
Width(mm) |
1270 |
1310 |
1110 |
1110 |
1310 |
1310 |
1900 |
Height(mm) |
1730 |
1840 |
1990 |
1940 |
2140 |
2140 |
2000 |
|
Depth(mm) |
1900 |
1500 |
2240 |
2440 |
2400 |
2600 |
4050 |
|
Material |
Interior |
Matte SUS #304 Stainless Steel Plates |
||||||
Exterior |
Powder coated carbon steel plates (With electrostatic spray coating) |
|||||||
Seal |
Imported Silicone Seal |
|||||||
Insulation |
Hard Polyurethane Foam Insulation and Glass Wool |
|||||||
Refrigerating system |
Compressor |
Copeland hermetic type compressor / BITZER semi-hermetic compressor, Zero Ozone Depletion Potential (ODP) Refrigerant |
||||||
Cooling method |
Air-cooled or Water-cooled Cooling Mode for Option |
|||||||
Controller |
Display: LED true color ultrathin touch screen, English menu, touch screen input |
|||||||
Safety precautions |
1) Adjustable over-temperature protection. 2) Test space temperature fuse. 3) Air conditioning channel limit over-temperature protection. 4) Fan motor overheating protection. 5) Heater over-current fast fuse. 6) Humidifier air-burning prevention protection switch. 7) Humidification Over-current circuit breaker. 8) Humidifier low water level protection. 9) Water tank low water level warning. 10) Total power phase sequence and phase loss protection k. Leakage protection, overload and short circuit protection. 11) Vacuum pump motor over-current and overload protection. |
|||||||
Standard configurations |
Transparent electrothermal film double-layer glass observation window *1 Lead holes*2, Lighting lamp*1, Casters*4, Stainless steel sample trays*2, Cable*1(2.5m) |
|||||||
Electrical supply |
AC 3ψ4W 380V 50HZ(R.S.T.N plus ground wire) (voltage fluctuation≦±10%) |
|||||||
▲Custom options available |
*Specifications of AHP Series Altitude test chamber (ATP series without humidity control.) |
||||||||
Model |
AHP-125 |
AHP-225 |
AHP-408 |
AHP-512 |
AHP-800 |
AHP-1000 |
AHP-2000 |
|
Temperature humidity adjustment mode |
Smart balanced temperature(humidity) control – BT(H)C |
|||||||
Performance |
Temperature range |
-20°C/-40°C/-70°C~+150°C |
||||||
Temperature fluctuation |
±0.5℃(At normal pressure) |
|||||||
Temperature uniformity |
±2.0°C (At normal pressure) |
|||||||
Temperature deviation |
±2.0℃(At normal pressure) |
|||||||
Cooling rate |
0.7°C~1.0°C/min (Overall average, at normal pressure) |
|||||||
Humidity range |
20%R.H~98%R.H (Work under normal pressure) |
|||||||
Humidity fluctuation |
±2.0%RH |
|||||||
Humidity uniformity |
±3.0%RH |
|||||||
Humidity deviation |
±3.0%RH (>75%RH), ±5.0%RH (≦75%RH) |
|||||||
Pressure range |
Normal pressure to 0.5kPa |
|||||||
Pressure deviation |
≦±2 kPa (≧40kPa),≦±5% (2 ~ 40kPa),≦±0.1 kPa(≦2kPa ) |
|||||||
Depressurization rate |
From normal pressure to 1kPa ≤30min |
|||||||
Pressure recovery rate |
10kPa/min(Adjustable) |
|||||||
Workspace volume |
125L |
225L |
408L |
512L |
800L |
1000L |
2000L |
|
Workspace dimensions (WxDxH)mm |
Width(mm) |
500 |
500 |
800 |
800 |
1000 |
1000 |
1000 |
Height(mm) |
500 |
750 |
850 |
800 |
1000 |
1000 |
1000 |
|
Depth(mm) |
500 |
600 |
600 |
800 |
800 |
1000 |
2000 |
|
Exterior dimensions (WxDxH)mm |
Width(mm) |
1270 |
1310 |
1110 |
1110 |
1310 |
1310 |
1900 |
Height(mm) |
1730 |
1840 |
1990 |
1940 |
2140 |
2140 |
2000 |
|
Depth(mm) |
1900 |
1500 |
2240 |
2440 |
2400 |
2600 |
4050 |
|
Material |
Interior |
Matte SUS #304 Stainless Steel Plates |
||||||
Exterior |
Powder coated carbon steel plates (With electrostatic spray coating) |
|||||||
Seal |
Imported Silicone Seal |
|||||||
Insulation |
Hard Polyurethane Foam Insulation and Glass Wool |
|||||||
Refrigerating system |
Compressor |
Copeland hermetic type compressor / BITZER semi-hermetic compressor, Zero Ozone Depletion Potential (ODP) Refrigerant |
||||||
Cooling method |
Air-cooled or Water-cooled Cooling Mode for Option |
|||||||
Controller |
Display: LED true color ultrathin touch screen, English menu, touch screen input |
|||||||
Safety precautions |
1) Adjustable over-temperature protection. 2) Test space temperature fuse. 3) Air conditioning channel limit over-temperature protection. 4) Fan motor overheating protection. 5) Heater over-current fast fuse. 6) Humidifier air-burning prevention protection switch. 7) Humidification Over-current circuit breaker. 8) Humidifier low water level protection. 9) Water tank low water level warning. 10) Total power phase sequence and phase loss protection k. Leakage protection, overload and short circuit protection. 11) Vacuum pump motor over-current and overload protection. |
|||||||
Standard configurations |
Transparent electrothermal film double-layer glass observation window *1 Lead holes*2, Lighting lamp*1, Casters*4, Stainless steel sample trays*2, Cable*1(2.5m) |
|||||||
Electrical supply |
AC 3ψ4W 380V 50HZ(R.S.T.N plus ground wire) (voltage fluctuation≦±10%) |
|||||||
▲Custom options available |